Gain Calculator
Choose the Offset
One direction: Offset = 0.2V
Bi-directional: Offset = 2.5V
Choose the Gain
1. Find the sensor's full scale output ratio (Ex.
2.00mV/V at 1000lb). Usually
printed on the load cell, or on the
calibration sheet.
2. This means that when 1000lb is applied, the sensor will
output 2.00mV
(0.002 V) for every Volt that is supplied for excitation.
3. Since the Techmor SG-1 excites with 5V, the full scale
output will be
2mV/V x 5V = 10mV.
4. Choose the desired output range, 0.2V to 4.8V is
good for 0-5V systems
So the amplifier output range is
4.6V.
5. Divide the desired amplifier output range by the sensor
full scale output.
Gain = 4.6V / 10mV = 460
6. If the sensor is bi-directional, divide this by 2
because it needs to go both
directions from 2.5V. Gain =
460/2 = 230
|